Pig Slaughter Line Throughput: 60, 120 and 240 Head per Hour

Station count, power, floor area and staffing across three throughput tiers, with the planning basis behind each range.

Throughput decides how many stations the line needs, how much rail the building has to carry, how much power and steam to reserve, and how many people stand on the floor each shift. Most enquiries fall into three sizes: 60, 120 and 240 head per hour. The ranges below are what we use for layout and budget discussions at each size, with the assumptions that make them valid.

Planning basis, 13 November 2026. Live weight 100–130 kg, carcass 75–95 kg, one 8-hour shift, 22 working days per month, line efficiency 85% of nominal. Change the shift pattern, the carcass range or the product mix and the numbers move. Treat them as a design starting point, not as a quotation.

Takt time is what actually sizes the line

Nominal rate converts to takt: 60 head/h is one head every 60 seconds, 120 is 30 seconds, 240 is 15 seconds. Each station has to finish its task inside that window. A line rated at 240 head/h with a 25-second dehairing cycle runs at 144 head/h, whatever the nameplate says.

Rail length follows the same arithmetic: heads per hour × hours on the rail × pitch per head. With 45–60 minutes on the rail and a 0.9–1.1 m pitch, 60 head/h needs about 45–65 m, 120 needs 90–130 m, and 240 needs 180–260 m once branches and rail returns are counted.

Planning ranges by nominal throughput (basis as stated above)
Item 60 head/h 120 head/h 240 head/h
Stations, staffed positions 12–14 18–22 26–30
Operators per shift 14–16 20–24 28–34
Installed power 55–75 kW 90–120 kW 150–200 kW
Running load 35–45 kW 55–75 kW 95–125 kW
Main process floor 350–450 m² 550–700 m² 900–1,200 m²
Steam 300–450 kg/h 600–850 kg/h 1,200–1,600 kg/h
Process water 1.2–1.8 m³/h 2.2–3.0 m³/h 4.0–5.5 m³/h
Chilling load 35–50 kW 65–90 kW 120–170 kW

What each size looks like on the floor

60 head/h. One chain, one stunning position, a single-unit scalder and one dehairing machine. Positions combine: the operator who bleeds also inspects, and evisceration shares a station with trimming. This is the size where a wide carcass range costs least, because a person adapts where a fixed conveyor cannot.

120 head/h. The common single-shift size. Stunning and bleeding separate, scalding and dehairing run continuously, and dressing needs a fixed sequence with two or three people on the same rail. A stoppage is felt within minutes, so the dehairing machine and the hoist are the two items to specify with most care.

240 head/h. Two dressing chains in parallel, or one chain worked from both sides, plus a second stunning position. Utilities grow faster than the head count: water and steam roughly double from 120 to 240 while floor area grows by about 70%, because circulation space, drain falls and inspection take the difference. Below a 15-second takt the hoist cycle and the rail transfers set the rate, not the operators.

Where the power and steam figures come from

Installed power is set by scalding heat, the dehairing drive, conveyors, hoists and the refrigeration interface. Running load sits at 60–70% of installed because the dehairing machine, hoists and conveyors work intermittently. Steam is the scalding load plus sanitation; a line that scalds at 60 °C for six minutes uses more steam than the head count alone suggests. Ask for the two figures separately. A quotation with one combined power number cannot be checked against the building supply.

Choosing between the three

  • Size the line to the shift pattern you will actually run, not to the busiest week of the year. A 240 head/h line run at 100 head/h for most of the year costs more in cleaning, maintenance and idle utilities than a 120 head/h line run at 100.
  • Keep 15–20% headroom above the rate you need. Below that, one absent operator or one carcass jammed in the dehairing machine pushes the whole shift.
  • Check the chilling side at the same time. A line that kills 240 head/h produces 240 carcasses that have to be chilled; the chilling load in the table is the constraint most often discovered late.
  • Confirm the carcass range with the actual animal supplier. A line built for 90 kg carcasses runs slower on 110 kg ones, and the difference shows at dehairing and at rail transfer.

Errors that appear after commissioning

  • A rate quoted without an efficiency figure. A nameplate rate is not shift output; 85% is what we plan with, and it still needs the carcass range and shift length next to it.
  • Stations counted as people. Combined positions mean fewer staff than stations at 60 head/h, and more staff than stations at 240 head/h where inspection is a dedicated role.
  • Steam and drain capacity left to the builder. Both are set by the line’s cycle times and neither can be added cheaply after the floor is poured.

For a first pass, send the intended shift pattern, the carcass weight range and the building’s available floor area. Those three answers place the project in one of the tiers above before any drawing is made. See the cost package breakdown for what sits outside the machine scope, and the layout inputs for the measurements the building has to provide.

Match the tier to your shift pattern

  • Send three numbers: heads per shift you need, carcass weight range, and the floor area available for the process room. Each tier above is defined by those three, not by the equipment list.
  • Separate utilities from machinery: steam, water and chilling are set by cycle times, so confirm them with the chilling and dispatch plan before the building services are fixed.
  • Check the two bottleneck items: the dehairing machine cycle and the hoist cycle decide the real rate at every tier.

Send the project requirements or start from the new pig abattoir plan. If the building already exists, the layout inputs page lists what to measure first.